Does anterior plating of the cervical spine predispose to adjacent segment changes?

Document Type

Journal Article

Publication Date

12-1-2005

Journal

Spine

Volume

30

Issue

24

DOI

10.1097/01.brs.0000190453.46472.08

Keywords

Adjacent segments; Anterior plating; Biomechanics; Intradiscal pressure

Abstract

Study Design. In a human cadaveric model, the effects of plate supplementation on the mechanical behaviors of adjacent segments were investigated. Objectives. The objective was to determine the effects of anterior cervical fusion and plating on the adjacent segments. Summary of Background Data. Increases in intradiscal pressure and intervertebral motion at adjacent segments have been reported in the lumbar spine following an instrumented fusion. It is unclear if the same phenomenon presents in the cervical spine. Methods. Seven human cadaveric cervical spines (C2-T1) were used, and fusion of the C5-C6 segment was chosen for the purpose of this study. Two miniature pressure transducers were implanted within each adjacent disc. Flexion, extension, lateral bending, and torsion loads up to 2.5 Nm were applied to the intact spine, and following each of the two procedures, anterior discectomy and grafted fusion, and anterior plating of the C5-C6 motion segment. Results. At the surgical level, a significant increase in segmental stiffness was observed after plating in all directions. Following the grafted fusion, there were no statistically significant changes at the superior adjacent segment, and there was a 13.7% increase in axial rotation in the inferior adjacent segment. Once anterior plating was applied, slight increase (<12%) over the intact spines was noted in lateral bending in both adjacent segments. However, there was no significant difference between the grafted fusion and anterior plated fusion at either adjacent segment. At both adjacent disc levels, the differences in intradiscal pressures between grafted fusion and plated fusion were less than 30% in all directions, and none of these differences was statistically significant. Conclusions. Intradiscal pressures and intervertebral motion at the adjacent levels are not significantly affected by the instrumented anterior fusion. The clinically observed degenerative change at adjacent segments in the cervical spine is more likely to be attributed to natural progression of the spondylotic process as opposed to biomechanical effect of the instrumentation or fusion. ©2005, Lippincott Williams & Wilkins, Inc.

This document is currently not available here.

Share

COinS