Surgical Retrieval of an Embolized Patent Ductus Arteriosus Closure Device in an Infant Weighing 1050 G

Document Type

Journal Article

Publication Date

9-22-2023

Journal

Interdisciplinary cardiovascular and thoracic surgery

DOI

10.1093/icvts/ivad162

Keywords

cardiopulmonary bypass; low birth weight; patent ductus arteriosus; prematurity

Abstract

UNLABELLED: The dislodgement of device during transcatheter procedure is a rare complication and the device can be retrieved by transcatheter techniques in most cases. In case of failed attempts, the surgery may be required and in haemodynamically unstable patients cardiopulmonary bypass may be unavoidable. A case of surgical retrieving of patent ductus arteriosus occlusion device from the right pulmonary artery in a 1050 g baby on CPB was presented. In literature CPB use in babies weighing under 1 kg has been rarely reported. CPB support was performed securely in our case who is one of the tiniest patients operated on. CPB can be safe enough in surgical approach of a complication of very low birth weight patient. CLINICAL REGISTRATION NUMBER/DATE/REGISTRY: Pro00015566-07/01/2021-Children's National Medical Center.