Document Type
Journal Article
Publication Date
11-28-2014
Journal
Clinical Ophthalmology
Volume
Volume 8
Inclusive Pages
2409-2414
DOI
10.2147/OPTH.S66898
Abstract
Context
Although Heidelberg retinal tomography (HRT)-generated topographic images have been studied extensively for the detection of retinal nerve fiber layer (RNFL) defects, little is known about the role of HRT-generated surface reflectivity images in the detection of RNFL defects in either patients with glaucoma or glaucoma suspects.
Aims
To evaluate the effectiveness of HRT version II (HRT II) optic nerve reflectivity images in uncovering RNFL defects in an outpatient population evaluated for glaucoma.
Study design/materials and methods
In 102 consecutive eyes from 60 patients evaluated for glaucoma in an academic-based practice, HRT II optic nerve images were prospectively imaged and compared with clinical optic nerve exam techniques to see if HRT II was able to detect RNFL defects overlooked in clinical practice.
Results
Nine eyes (8.8%) were found to have RNFL defects recognized by screening with HRT II. Of these nine eyes, eight (88.9%) were recognized to demonstrate RNFL defects by conventional examination techniques. One additional eye had an RNFL defect seen on physical exam that was not detected by HRT.
Conclusion
In academic practice, HRT II may be helpful in complementing conventional exam techniques in the recognition and documentation of acquired RNFL loss.
Creative Commons License
This work is licensed under a Creative Commons Attribution-Noncommercial 4.0 License
APA Citation
Belyea, D.A., Alhabshan, R.N., Mahesh, S.P., Gertner, G.S., Ibisevic, M.M. et al. (2014). Utility of Heidelberg retinal tomography as a screening tool for analyzing retinal nerve fiber layer defects. Clinical Ophthalmology, 8, 2409-2414.
Peer Reviewed
1
Open Access
1
Comments
Reproduced with permission of Dovepress. Clinical Ophthalmology.