Clinical outcomes, toxicity, and cosmesis in breast cancer patients with close skin spacing treated with accelerated partial breast irradiation (APBI) using multi-lumen/catheter applicators

Document Type

Journal Article

Publication Date

1-1-2016

Journal

Journal of Contemporary Brachytherapy

Volume

8

Issue

6

DOI

10.5114/jcb.2016.64830

Keywords

APBI; Breast cancer; Skin spacing

Abstract

Purpose: Accelerated partial breast irradiation (APBI) using a single-lumen device is associated with better cosmetic outcomes if the spacing between the applicator and skin is > 7 mm. However, there are no reports addressing the late toxicity and clinical outcomes in patients treated with single-entry multi-lumen/catheter applicators who had close skin spacing (7 mm or less). We undertook this study to report clinical outcome, acute and late toxicity as well as cosmesis of early stage breast cancer patients with close skin spacing treated with APBI using multi-lumen or multi-catheter devices. Material and methods: This is a retrospective study of all breast cancer patients who had undergone APBI using single-entry multi-lumen/catheter devices in a single institution between 2008 to 2012. The study was limited to those with ≤ 7 mm spacing between the device and skin. Results: We identified 37 patients and 38 lesions with skin spacing of ≤ 7 mm. Seven lesions (18%) had spacing of ≤ 3 mm. Median follow-up was 47.5 months. There was one case of ipsilateral breast recurrence and one ipsilateral axillary recurrence. Based on RTOG criteria, 22 treated lesions experienced grade 1 and 9 lesions experienced grade 2 toxicity. Twenty-one lesions experienced late grade 1 toxicity. One patient had to undergo mastectomy due to mastitis. Twenty-four treated breasts showed excellent and 11 had good cosmetic outcome. Overall cosmesis trended towards a significant correlation with skin spacing. However, all patients with ≤ 3 mm skin spacing experienced acute and late toxicities. Conclusions: Accelerated partial breast irradiation can be safely performed in patients with skin spacing of ≤ 7 mm using single-entry multi-lumen/catheter applicators with excellent cosmetic outcomes and an acceptable toxicity profile. However, skin spacing of ≤ 3 mm is associated with acute and late toxicity and should be avoided if possible.

This document is currently not available here.

Share

COinS